EHR Backup and Disaster Recovery for Optometry: What to Ask
Ask your EHR or IT vendor for three things in writing: how much recent data you could lose (RPO), how long recovery takes (RTO), and proof of a recent test restore. In the US, HIPAA requires a data backup plan and a disaster recovery plan, and a cloud contract does not remove that duty from the practice.
Step-by-step
- Pick a date and an owner — Choose a quiet half day and name one person responsible for the result. You now have a test that will actually happen.
- Choose what to restore — Include the EHR database, a folder of images and one non-EHR system such as the accounting file.
- Restore to a separate machine or test environment — Never restore over the live system. For a cloud EHR, ask the vendor to restore your data to a test site or supply a dated restore report.
- Time the restore — Note when you started and when a user could open a record. The difference is your measured recovery time.
- Check the content — Open five known patients, including one seen on the day of the backup. Confirm the latest exam, an image, a prescription and a balance.
- Check the gap — Compare the newest record in the restored copy with the live system. The difference is your measured recovery point.
- Record the result and fix failures — Write down the date, the tester, both measurements and any failure, and keep the record with your HIPAA security documentation.
On this page
- What HIPAA Requires of Your Backups (US)
- RPO and RTO: The Two Numbers to Get in Writing
- Cloud or Local Server: Who Does the Work
- If your EHR is in the cloud
- If your EHR is on a local server
- Questions to Ask Your EHR or IT Vendor
- How to Run a Restore Test
- Why Backups Matter in a Ransomware Attack
- What a Proposed US Rule Would Change
- Our Recommendation
- Sources
A backup protects your practice only if you can restore from it, within a time you have agreed in writing, and you have seen that work. Whether your EHR runs in the cloud or on a server in the back office, ask for three things: how much recent data you could lose, how long you would be down, and proof of a recent test restore. In the United States the HIPAA Security Rule makes a backup plan and a disaster recovery plan required, and using a cloud vendor does not move that duty off your desk.
This is a guide to a software and contract decision, not legal advice. The rules quoted here are US federal rules. Confirm your own obligations with a healthcare attorney or your privacy regulator.
What HIPAA Requires of Your Backups (US)
The requirement sits in the Security Rule's contingency plan standard, 45 CFR 164.308(a)(7). It has five parts, and the rule labels each one:
- Data backup plan (Required): "Establish and implement procedures to create and maintain retrievable exact copies of electronic protected health information."
- Disaster recovery plan (Required): "Establish (and implement as needed) procedures to restore any loss of data."
- Emergency mode operation plan (Required): procedures to keep critical business processes running, and patient data protected, while you work in emergency mode.
- Testing and revision procedures (Addressable): "Implement procedures for periodic testing and revision of contingency plans."
- Applications and data criticality analysis (Addressable): rank which systems and data matter most, so you know what to restore first.
"Addressable" is not a polite word for optional. Under 45 CFR 164.306(d) you must assess whether the measure is reasonable and appropriate for your practice. If it is not, you document why and use an equivalent alternative where one is reasonable. Our HIPAA checklist for optometry EHRs covers the rest of the rule.
You also need an emergency access procedure, which is required: a way of "obtaining necessary electronic protected health information during an emergency" (45 CFR 164.312(a)(2)(ii)). Before you move equipment that holds patient data, such as a server swap, make a retrievable, exact copy "when needed" (45 CFR 164.310(d)(2)(iv), addressable).
The rule sets no backup frequency and no restore deadline. Those come from your own risk analysis and your contract.
Outside the United States HIPAA does not apply, but the questions below still do. Check your own privacy law for record-keeping and breach duties; our guide to optometry software in Canada covers the Canadian position.
RPO and RTO: The Two Numbers to Get in Writing
The US National Institute of Standards and Technology (NIST) defines both in its contingency planning guide, SP 800-34.
- Recovery point objective (RPO) is "the point in time to which data must be recovered after an outage" (NIST glossary). In practice it is how much recent work you can afford to lose. An RPO of 24 hours means that, in the worst case, you re-enter a day of exams, orders and payments.
- Recovery time objective (RTO) is the length of time a system can be in recovery before the disruption harms the organization (NIST glossary). In practice it is how long you can run without the EHR.
We do not quote typical figures here, because the only figures that count are the ones in your contract. Ask each vendor for its RPO and RTO, ask whether they are commitments or targets, and ask what you receive if they are missed.
Set your own tolerance first. Decide how many hours without records, recalls and claims you could accept, and how much data you could re-key.
Cloud or Local Server: Who Does the Work
The choice changes who performs the backup. It does not change who answers for it.
If your EHR is in the cloud
The vendor runs the backups, so your protection is the contract. HHS guidance on HIPAA and cloud computing says a cloud provider that stores patient data is a business associate, even when it holds only encrypted data and no key. You need a business associate agreement (BAA) with it.
The same guidance lists what a service level agreement can cover: "system availability and reliability", "back-up and data recovery", the "manner in which data will be returned to the customer after service use termination", and security responsibility. HHS also says a provider must not impermissibly block or terminate your access to the data.
The BAA itself must require the vendor to report security incidents to you (45 CFR 164.314(a)) and, at termination, to return or destroy patient data if feasible (45 CFR 164.504(e)). Neither clause says how fast you get a usable copy, so add that yourself.
Two things stay with you in any cloud setup. One is the internet connection, since a cloud EHR is unreachable without it. The other is data that never reaches the EHR: images held on a retinal camera or OCT workstation, scanned documents on a shared drive, and the accounting file.
If your EHR is on a local server
You, or the IT firm you pay, own every step: the backup job, the off-site copy, the encryption key and the test. An IT firm that stores or maintains patient data for you, backups included, is a business associate too, and needs a BAA.
A long-standing rule of thumb is the 3-2-1 rule. A paper produced for US-CERT, Data Backup Options (2012), puts it this way: keep 3 copies of any important file, on 2 different media types, with 1 copy off site.
Ransomware adds a fourth condition. The CISA #StopRansomware Guide tells organizations to "maintain offline, encrypted backups of critical data", because many ransomware variants look for reachable backups and delete or encrypt them. A USB drive that stays plugged into the server is not offline.
For the wider trade-offs between the two models, see our comparison of cloud-based and server-based optometry EHRs.
Questions to Ask Your EHR or IT Vendor
Ask these before you sign and at renewal. The "good answer" column is our editorial view, not a legal standard.
| Question | A good answer looks like | Why it matters |
|---|---|---|
| How often is our data backed up, and what is the RPO? | A stated interval and an RPO written into the agreement | It sets how much work you re-enter after a failure |
| What is the RTO, and is it a commitment? | A figure in the service level agreement, with a remedy if it is missed | A target costs the vendor nothing to miss |
| Where are backups kept, and is one copy offline or unchangeable? | Copies in a separate location, with at least one that ransomware on the main system cannot reach | Attackers go after reachable backups first |
| When did you last test a full restore, and can we see the result? | A dated test record, and a restore of your own data on request | An untested backup is a hope, not a plan |
| Are images and attached documents in the backup? | A written list of what is included and what is not | Device images often sit outside the EHR database |
| How will you tell us about an outage or a security incident, and how fast? | A named contact, a stated time limit and a status page | Your own 60-day breach clock depends on being told |
| If we leave, or you close, how do we get our data? | A full export in a documented format, with a stated price and timescale | The rule requires return or destruction, not a usable export |
| Can we read records while the system is down? | A read-only copy, a downtime report or a documented emergency procedure | You need emergency access to patient data |
Put these alongside the wider checks in our guide on how to evaluate an optometry software vendor. The export question matters most on the day you move, as how to switch optometry EHR explains.
How to Run a Restore Test
A restore test means recovering real data from a backup into a separate place and checking that it is complete and usable. HHS says in its ransomware fact sheet that "test restorations should be periodically conducted to verify the integrity of backed up data". The steps below are our suggested routine for a small practice.
- Pick a date and an owner. Choose a quiet half day and name one person responsible.
- Choose what to restore. Include the EHR database, a folder of images and one non-EHR system such as the accounting file.
- Restore to a separate machine or test environment. Never restore over the live system. For a cloud EHR, ask the vendor to restore your data to a test site or to supply a dated restore report.
- Time it. Note when you started and when a user could open a record. That is your measured recovery time.
- Check the content. Open five known patients, including one seen on the day of the backup. Confirm the latest exam, an image, a prescription and a balance.
- Check the gap. Compare the newest record in the restored copy with the live system. That is your measured recovery point.
- Record and fix. Write down the date, who tested, both results and any failure. Keep the record with your HIPAA security documentation, which the Security Rule requires you to retain for 6 years (45 CFR 164.316(b)(2)).
The current rule calls for "periodic" testing and sets no interval. Our suggestion is at least once a year, and again after any server, vendor or backup change.
Why Backups Matter in a Ransomware Attack
Backups decide how long you are closed. They do not settle the breach question. HHS says that when ransomware encrypts patient data, a breach is presumed unless you can show a "low probability that the PHI has been compromised" through a documented risk assessment.
If notification is required, affected patients must be told without unreasonable delay and no later than 60 calendar days after discovery (45 CFR 164.404). A breach affecting 500 or more people is reported to HHS at the same time (45 CFR 164.408). State breach laws also apply, so take legal advice early.
What a Proposed US Rule Would Change
HHS published a proposed rewrite of the Security Rule on 6 January 2025. It would remove the required and addressable labels and add specific numbers. Backup copies would be no more than 48 hours older than live data. Practices would need written procedures to restore critical systems and data within 72 hours of a loss. A sample of backed-up data would be test-restored at least monthly.
None of this is in force. The regulation text we read, dated 20 November 2026, contains none of these figures, and we make no prediction about a final rule.
Our Recommendation
Choose on evidence, not on the hosting model. If you have no IT support and a reliable internet connection, a cloud EHR with RPO, RTO, export and incident terms written into the agreement is the lower-risk choice. If you keep a local server, budget for an off-site and offline copy and a named person who tests it. In both cases, run one restore test before you sign or renew, and keep the record.
Next, read our HIPAA compliance checklist for optometry EHRs for the security features to check alongside backup.
Sources
- 45 CFR Part 164, Subpart C (HIPAA Security Rule), sections 164.306, 164.308, 164.310, 164.312, 164.314 and 164.316, and sections 164.404, 164.408 and 164.504 of the same part, eCFR text dated 20 November 2026.
- HHS, Fact Sheet: Ransomware and HIPAA, content last reviewed 20 September 2021.
- HHS, Guidance on HIPAA and Cloud Computing, content last reviewed 23 December 2022.
- NIST SP 800-34 Rev. 1, Contingency Planning Guide for Federal Information Systems (May 2010), and the NIST glossary entries drawn from it.
- CISA, #StopRansomware Guide.
- Ruggiero and Heckathorn, Data Backup Options, produced for US-CERT, 2012.
- HHS, proposed rule, 90 FR 898, published 6 January 2025.
All sources were read on 28 November 2026.